Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Portal frames

Which of the following situations should be verified as an accidental combination of actions?

Snow removed from one roof slope
Snow accumulating behind a parapet
Snow on the roof if the altitude is above 150 m
Snow accumulating in a valley

When should a portal frame be used for the gable frame?

When future extension is anticipated
For aesthetic reasons
To save weight
So that gable columns are not required

When verifying the rafter, which two zones are likely to be critical for lateral-torsional buckling?

Adjacent to the haunch, in the gravity combination of actions
Around the point of contraflexure
At the maximum sagging moment, near the apex
Adjacent to the haunch, in the reversal combination of actions

What is the primary objective for fire design if a portal frame is adjacent to a boundary?

To prevent loss of life
To prevent early collapse of the structure
To prevent fire spread to the adjoining property
To prevent the release of noxious fumes

How can second-order effects in portal frames be allowed for?

By using a second-order analysis
By amplifying the lateral loads
By using S355 steel
By down-rating member resistance by 10%

What steps are effective in reducing the calculated deflections at SLS?

Modelling the stiffness of nominally pinned bases
Using higher strength steels
Using members with a higher inertia
Adding restraints

If a member is not adequate when checking lateral-torsional buckling, what steps are effective in increasing the resistance?

Provide additional restraints
Reduce the spacing of the restraints
Select a larger and heavier member
Use higher grade steel

What is the primary function of an eaves haunch?

To facilitate a bolted connection
To increase the shear resistance at the support
To increase the bending resistance of the rafter section
To reduce deflections

How should purlins be located?

At spaces less than the maximum spaces specified by the cladding manufacturer
Spaced equally between the eaves and the apex
Judiciously, to suit the restraint to the rafter
At 1.75m centres

The adjustments to αcr in the calculation of αcr,est allow for what phenomena?

The high moment and shear combined
The flexibility of the structure
The axial load in the columns and rafters