Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Design for fire

The dominant mechanism which enables a composite steel deck floor to enhance its load carrying capacity at large deflections is based on what?

Tensile membrane action in the slab
Catenary action in the beams
Robust connections
Thermal gradients in the slab

Which of the following statements is correct?

The standard fire test is always a good representation of what happens in a real building fire.
A standard fire test on composite steel deck floors is a good indicator of how these floors will behave in real fires.
Continuous composite steel deck floors generally have much greater strength in fire than is indicated by the standard fire test on isolated elements.
The standard fire test is unsafe.

Which of the following is/are not considered a major risk factor in fire in BS9999, the new British Standard published to provide an alternative approach to the design of fire precautions in buildings to those in Government published documents?

Whether the occupants of the building are familiar with their surroundings.
Whether the occupants of the building are likely to be asleep
Where there is not a fire station nearby
The height of the building

Which of the following are commonly used to provide fire protection of structural beams and columns in the UK?

Boards
Sprays
Thin film intumescent coatings
Reinforcing steel and concrete between the flanges

A new British Standard, BS 9999, has been published to provide an alternative approach to the design of fire precautions in buildings to those in Government published documents. Does BSI describe it as being?

Based on structured risk based design
Based on conservative experience
Based on European approaches to the design of fire precautions in buildings
Based on an averaged approach from across the regions of the UK

Where a single storey building must retain stability to prevent fire spread to adjacent buildings (i.e. a boundary condition), the most efficient method of designing is usually to?

Fire protect the whole building
Fire protect the stanchions along the affected wall(s) and design the bases to resist the overturning moment from collapse of the unprotected rafters
Fire protect selected frames of the building
Rely on the owner of the adjacent building to install cladding capable of resisting the fire spread

Which is the most common form of structural fire protection used in the UK?

Boards
Sprays
Thin film intumescent coatings
Flexible blankets

Which of the following is/are true?

Approved Document B must be used in the design of fire precautions in England?
The use of Approved Document B for the design of fire precautions in buildings in England is deemed to satisfy the requirements of the Building Regulations.
It is not necessary to use Approved Document B for the design of fire precautions in England if it can be shown that you have met the requirements of the Building Regulations in some other way.
The use of Approved Document B does not guarantee that all buildings will be safe in fire

What is the word or phrase used to describe the moment when simultaneous ignition of the contents of a fire compartment takes place?

Super ignition
Flashover
Auto ignition
Pyrolysis

The maximum period of fire resistance required in the documents published by Government across the UK to help meet the requirements of their Building Regulation is?

60 minutes
90 minutes
120 minutes
240 minutes