Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Worked examples to EC3

Having calculated the non-dimensional slenderness, how might the reduction factor, χ, be determined?

Using the expressions given in EN 1993
Using the figure given in EN 1993
Using look-up tables in NCCI
Using look-up tables in EN 1993

Which class of sections use the Gross Area, A when calculating the resistance?

Class 1
Class 2
Class 3
Class 4

Which bending modulus should be used with a Class 2 section?

Elastic modulus
Plastic Modulus
Effective Modulus
Young's Modulus

How is ε calculated?

No need - its given in the tables
ε = (235/fy)1/2
ε = (275/fy)1/2
ε = (355/fy)1/2

Which partial factor should be used when calculating buckling resistance?

γM0
γM1
γM2
It depends on the mode of buckling

When classifying the flange of a section, what is dimension c in the ratio c/t?

Half the flange width
Half the flange width, less half the web thickness
Half the flange width, less half the web thickness, less the root radius
Half the flange width, less the web thickness

In expressions 6.61 and 6.62, what structural mechanics do the k factors account for?

The residual stresses in the member
The shape of the bending moment diagram
The influence of the axial load
The section shape

When calculating the cross-sectional resistance of a member, what is the value of the partial factor, γM0 specified in the UK National Annex?

1.0
1.05
1.1
1.15

When is the factor αLT used?

When calculating flexural buckling resistance
When calculating lateral-torsional buckling resistance
When classifying webs subject to axial load and bending
When calculating torsional buckling resistance

When designing, which country's National Annex should be used?

No NA is needed if the recommended values are chosen
The NA for the country where design is carried out
The NA for the country where construction is to be carried out
The choice of NA should be specified by the client