Worked examples to EC3 quiz

From SteelConstruction.info
Revision as of 12:11, 12 March 2019 by Chris.dolling@steelconstruction.org (talk | contribs) (Created page with "Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Worked examples to EC3

Which class of sections use the Gross Area, A when calculating the resistance?

Class 1
Class 2
Class 3
Class 4

Why does torsional-flexural buckling not apply to UKC sections?

It does, but it's never critical
Because UKC sections have a high torsional rigidity
Because the flanges are relatively thick
Because UKC sections are not asymmetric

Which partial factor should be used when calculating buckling resistance?

γM0
γM1
γM2
It depends on the mode of buckling

Which combination of checks are required for elements in tension?

Gross area using yield strength, and γM0
Gross area using yield strength, and γM1
Net area using yield strength, and γM1
Net area using ultimate strength and γM2

When classifying the flange of a section, what is dimension c in the ratio c/t?

Half the flange width
Half the flange width, less half the web thickness
Half the flange width, less half the web thickness, less the root radius
Half the flange width, less the web thickness

When must the moment resistance of a section be reduced due to shear?

When the maximum design shear force coincides with the maximum design moment
When the design shear is more than 60% of the shear resistance
When the design shear is more than 50% of the shear resistance
Whenever UKB are specified, due to the thin web

What structural mechanics is allowed for in the C1 factor when calculating Mcr?

The influence of the axial load
The influence of residual stresses
The shape of the bending moment diagram
Initial imperfections in the member

When is the factor αLT used?

When calculating flexural buckling resistance
When calculating lateral-torsional buckling resistance
When classifying webs subject to axial load and bending
When calculating torsional buckling resistance

For designs to be constructed in the UK, where should the steel strength be taken from?

The designer may choose
The UK National Annex to BS EN 1993-1-1
The product Standard
BS EN 1993-1-1

Which bending modulus should be used with a Class 2 section?

Elastic modulus
Plastic Modulus
Effective Modulus
Young's Modulus