Difference between revisions of "Introduction to EC3 quiz"

From SteelConstruction.info
 
Line 3: Line 3:
 
'''Good luck'''
 
'''Good luck'''
 
{{#psy_quiz:introduction-to-ec3}}
 
{{#psy_quiz:introduction-to-ec3}}
 +
 +
[[Category:CPD]]

Latest revision as of 12:11, 12 March 2019

Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Introduction to EC3

What value of ξ is specified in the UK National Annex?

The recommended value of 0.85
0.925
0.950
0.875

If a web is Class 3 and a flange is Class 1, what Class is the section?

There must be some mistake; both elements should be the same Class
Class 1
Class 2
Class 3

Must all connections be classified by calculation?

No, classification by experience of satisfactory performance is permitted
Only for elastic design
Only for plastic design
Only if being used outside the UK

Which forms of buckling might apply to a UKC, subject to an axial compression and a bending moment?

Flexural
Torsional
Torsional-flexural
Lateral-torsional

What structural mechanics is allowed for in the C1 factor when calculating Mcr?

The influence of the axial load
The influence of residual stresses
The shape of the bending moment diagram
Initial imperfections in the member

When can the Eurocodes be used?

When Approved Document A in the Building Regulations is revised
Only when the client specifies design to the Eurocodes
Immediately
Only for projects outside the UK

What does a value of αcr = 11 indicate?

A very sensitive frame
That second-order analysis must be used
That the second-order effects are small enough to be ignored
That the approximate allowances for second-order effects cannot safely be used

Which of the following statements about columns in 'simple construction' are correct?

Only open sections (UKC) can be used
Design moments in the columns are based on nominal eccentricities
Beams are designed as simply supported
The approach cannot be used in Eurocode design

When calculating the buckling resistance of a member what is the value of the partial factor, γM1 specified in the UK National Annex?

1.0
1.05
1.1
1.15

In expressions 6.61 and 6.62, what structural mechanics do the k factors account for?

The residual stresses in the member
The shape of the bending moment diagram
The influence of the axial load
The section shape