Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Fire and steel construction

Which is the most common form of structural fire protection used in the UK?

Boards
Sprays
Thin film intumescent coatings
Flexible blankets

Fire protection thickness is a function of the section factor of the beam or column. Which of these statements are correct?

The section factor is the cross sectional area in square metres divided by the heated perimeter in metres.
The section factor is the heated perimeter in metres divided by the cross sectional area in square metres.
Short stocky sections will typically have higher section factors than tall, skinny sections.
Fire protection thickness decreases as section factor decreases.

Which of the following statements are correct?

Fire safety engineering can provide an alternative approach to fire safety to that given in Government published documents such as Approved Document B.
For some buildings, the provisions of documents such as Approved Document B for the design of fire precautions are inadequate and a fire safety engineering approach must be used.
For some buildings, the provisions of documents such as Approved Document B for the design of fire precautions may not be adequate and a fire safety engineering approach may be the only viable way to a satisfactory standard of fire safety.
Fire safety engineering has wide applications in finding solutions to particular problems in the design of fire precautions

How does an element of construction demonstrate that it can perform a fire resisting function if required?

Through trial and error in real building fires
Through a detailed theoretical study
Via a fire test carried out in accordance with a standard acceptable in the country in which that element is to be used
Via tests carried out in the manufacturer’s own furnaces

Which of the following is not considered a major risk factor in fire in BS 9999, the new British Standard published to provide an alternative approach to the design of fire precautions in buildings to those in Government published documents?

Whether the occupants of the building are familiar with their surroundings.
Whether the occupants of the building are likely to be asleep
Where there is likely to be a fire station nearby
The height of the building

What was given as the common maximum dry film thickness for thin film intumescent coatings that can be applied in one pass?

1200 microns
1500 microns
1800 microns
2000 microns

Which form of fire protection is most commonly used to fire protect structural steelwork for buildings off-site?

Boards
Sprays
Thin film intumescent coatings
Flexible blankets

What is the meaning of time equivalent in fire engineering?

It is the severity of a fire in a compartment in terms of exposure to a standard fire test
It is the time in minutes at which the fire in a compartment will burn above 600°C
It is the period for which a fire will burn based on times measured in other, equivalent, compartments
It is the period of time which is required for the fire brigade to attend and extinguish a compartment fire.

Use of the advanced methods of structural fire engineering developed from the Cardington fire tests will usually lead to what?

No fire protection on the beams or columns
No fire protection on any of the beams
No fire protection on most of the secondary beams
Reduced fire protection on the secondary beams.

The maximum period of fire resistance required in Approved Document B to help meet the requirements of the Building Regulation is?

60 minutes
90 minutes
120 minutes
240 minutes