Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Portal frames

What best describes a portal frame structure?

Frames of simple construction
3-d continuous structures
Continuous frames in-plane, braced in the longitudinal direction
Continuous frames, braced in-plane

Which of the following situations should be verified as an accidental combination of actions?

Snow removed from one roof slope
Snow accumulating behind a parapet
Snow on the roof if the altitude is above 150 m
Snow accumulating in a valley

How can second-order effects in portal frames be allowed for?

By using a second-order analysis
By amplifying the lateral loads
By using S355 steel
By down-rating member resistance by 10%

Why are Anti-sag systems used with purlins?

To control the vertical deflection of the purlins
To control deflection down the slope, and assist the alignment of the purlins
To provide restraint to the bottom flange of the purlin in an uplift combination of actions
So that the manufacturer's warranty is not invalidated

How long should the haunch be?

To the third purlin
Until the hogging bending moment is approximately the same as the sagging moment
Three times as long as its depth
One third of the column height

How should purlins be located?

At spaces less than the maximum spaces specified by the cladding manufacturer
Spaced equally between the eaves and the apex
Judiciously, to suit the restraint to the rafter
At 1.75m centres

The adjustments to αcr in the calculation of αcr,est allow for what phenomena?

The high moment and shear combined
The flexibility of the structure
The axial load in the columns and rafters
The base fixity

What does an 'unrestrained' column imply?

No intermediate restraints to the inside flange can be provided
There is no stiffener at the connection
There are no side rails
The bracing is attached in a different bay

How is a moment-resisting base commonly detailed for the fire condition, if necessary?

With a thicker base plate
With more holding down bolts
Set into a pocket cast in the base
Provided with stiffeners

When verifying the rafter, which two zones are likely to be critical for lateral-torsional buckling?

Adjacent to the haunch, in the gravity combination of actions
Around the point of contraflexure
At the maximum sagging moment, near the apex
Adjacent to the haunch, in the reversal combination of actions