Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Portal frames

How can second-order effects in portal frames be allowed for?

By using a second-order analysis
By amplifying the lateral loads
By using S355 steel
By down-rating member resistance by 10%

Which of the following situations should be verified as an accidental combination of actions?

Snow removed from one roof slope
Snow accumulating behind a parapet
Snow on the roof if the altitude is above 150 m
Snow accumulating in a valley

How is a moment-resisting base commonly detailed for the fire condition, if necessary?

With a thicker base plate
With more holding down bolts
Set into a pocket cast in the base
Provided with stiffeners

When might the inside of a gable column be in compression?

When the gable is the leeward face of the building
When the wind direction is parallel to the gable
When there is a large internal pressure
When the gable is on the windward face of the building

What is the primary objective for fire design if a portal frame is adjacent to a boundary?

To prevent loss of life
To prevent early collapse of the structure
To prevent fire spread to the adjoining property
To prevent the release of noxious fumes

If a member is not adequate when checking lateral-torsional buckling, what steps are effective in increasing the resistance?

Provide additional restraints
Reduce the spacing of the restraints
Select a larger and heavier member
Use higher grade steel

When should the junction of the inside face of the column and the underside of the haunch be restrained?

Only in the gravity combination of actions
Always
If there is not a side rail and compression stiffener at that level
If a side rail can be provided at that level

How should purlins be located?

At spaces less than the maximum spaces specified by the cladding manufacturer
Spaced equally between the eaves and the apex
Judiciously, to suit the restraint to the rafter
At 1.75m centres

What value of base stiffness is recommended when modelling nominally pinned bases?

Zero - it's a pinned base
Zero - at ULS
10% of the column stiffness when calculating frame stability
20% of the column stiffness when considering SLS

What is the primary function of an eaves haunch?

To facilitate a bolted connection
To increase the shear resistance at the support
To increase the bending resistance of the rafter section
To reduce deflections