Please answer the following 10 multiple choice questions, then click 'submit' to check the result. The pass mark for a CPD certificate is 8 out of 10, and you may retake the quiz as many times as you wish, but the questions will vary! Please note that one, two, three or all of the possible answers presented for each question may be right, and to gain a mark for that question all correct answers must be identified.

Good luck

Design for fire

The dominant mechanism which enables a composite steel deck floor to enhance its load carrying capacity at large deflections is based on what?

Tensile membrane action in the slab
Catenary action in the beams
Robust connections
Thermal gradients in the slab

Which of the following is not a correct conclusion following the Cardington fire tests?

That composite steel deck construction has significantly greater reserves of strength than is indicated by tests of individual members
That columns are critical stabilising elements and must be protected
That all beams supporting composite steel deck floors do not need to be protected in order to prevent structural collapse in fire
That the results are applicable to forms of construction other than steel frames with composite steel deck floors.

A new British Standard, BS 9999, has been published to provide an alternative approach to the design of fire precautions in buildings to those in Government published documents. Does BSI describe it as being?

Based on structured risk based design
Based on conservative experience
Based on European approaches to the design of fire precautions in buildings
Based on an averaged approach from across the regions of the UK

What is the word or phrase used to describe the moment when simultaneous ignition of the contents of a fire compartment takes place?

Super ignition
Flashover
Auto ignition
Pyrolysis

Which is the most common form of structural fire protection used in the UK?

Boards
Sprays
Thin film intumescent coatings
Flexible blankets

Which of the following is/are true?

Approved Document B must be used in the design of fire precautions in England?
The use of Approved Document B for the design of fire precautions in buildings in England is deemed to satisfy the requirements of the Building Regulations.
It is not necessary to use Approved Document B for the design of fire precautions in England if it can be shown that you have met the requirements of the Building Regulations in some other way.
The use of Approved Document B does not guarantee that all buildings will be safe in fire

The most widely used source of information for the design of fire precautions in buildings in England is?

Technical Handbook 2
Approved Document B
Technical Booklet E
BS9999

Which of the following describes the building at Cardington in which the major fire test programme was carried out between 1994 and 2003?

Non-composite steel frame with precast planks
Steel frame with Slimdek beams
Steel frame with composite steel deck floors
Post tensioned flat slab

Structural steel in single storey buildings does not generally require fire protection. Which of these situations is not an exception to that rule?

The steel is in an external wall which must retain stability to prevent fire spread to adjacent buildings
The steel forms part of a compartment wall or the enclosing structure of a protected zone
The building contains a valuable cargo which must be protected and so the building must be protected against collapse
The steel forms part of a separating wall

In which areas of the UK are sprinklers not mandatory in buildings over 30 metres in height?

England & Wales
Scotland
Northern Ireland
All of the above